Article ID Journal Published Year Pages File Type
10716053 Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 2009 5 Pages PDF
Abstract
A transportable neutron radiography system, incorporating a SbBe neutron source, has been simulated using the MCNPX code. Design provisions have allowed two radiography systems to be utilised using the same SbBe neutron source. In this respect, neutron radiographies can be carried out using the photoneutrons produced when the 124Sb is surrounded by the Be target. Alternatively, γ-radiography can be utilised with the photons from the 124Sb with the target removed. Appropriate collimators were simulated for each of the radiography modes. Apart from Be, the materials considered were compatible with the European Union Directive on 'Restriction of Hazardous Substances' (RoHS) 2002/95/EC, hence excluding the use of cadmium and lead. Bismuth was chosen as the material for γ-radiation shielding and the proposed system allowed a maximum activity of the 124Sb up to 1.85×1013 Bq. The system simulated allows different object sizes to be studied with a wide range of radiography parameters.
Related Topics
Physical Sciences and Engineering Physics and Astronomy Instrumentation