| Article ID | Journal | Published Year | Pages | File Type | 
|---|---|---|---|---|
| 10716319 | Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment | 2005 | 9 Pages | 
Abstract
												This paper describes the proton irradiation and subsequent analysis of 8 e2v technologies CCD65 L3Vision devices with the intention of assessing the suitability of L3Vision technology to applications in space. In particular the use of L3Vision charge coupled devices (CCDs) on the Radial Velocity Spectrometer (RVS) instrument of the planned European Space Agency GAIA mission is discussed. The operational properties of the devices were characterised before irradiation with protons to a 10 MeV equivalent fluence of 2.5Ã109protonscm-2. The devices were then characterised again before undergoing a second proton irradiation which increased the total 10 MeV equivalent proton fluence received by each device to 2.1Ã1010protonscm-2. All 8 devices functioned as expected after each irradiation, with no catastrophic failures occurring even after the second irradiation which increased the total proton fluence to approximately 10 times the expected 6 year RVS fluence.
											Related Topics
												
													Physical Sciences and Engineering
													Physics and Astronomy
													Instrumentation
												
											Authors
												D.R. Smith, A.D. Holland, 
											