Article ID Journal Published Year Pages File Type
10716511 Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 2005 9 Pages PDF
Abstract
This paper presents a Hall probe mapping system for measuring a cyclotron magnet, which has been fabricated for the 13 MeV cyclotron at the Korea Institute of Radiological and Medical Sciences. Two Hall probes are mounted on a precision mechanical x-y stage and map magnetic field in the Cartesian coordinate system. The mapping system uses the 'flying' mode field mapping method to reduce data-acquisition time. The time required for mapping the whole gap-area of the cyclotron magnet is ∼60 min. The relative measurement error for the averaged magnetic field along beam orbit is less than 0.02%. The cyclotron magnet has been corrected using field measurement data, and the achieved total phase excursion of the cyclotron after correction is less than ±15°, which is within the tolerance of ±20° for the total phase excursion.
Related Topics
Physical Sciences and Engineering Physics and Astronomy Instrumentation
Authors
, , , , , , ,