Article ID Journal Published Year Pages File Type
11017535 Journal of Rock Mechanics and Geotechnical Engineering 2018 9 Pages PDF
Abstract
Assessment of the reinforcement behavior of soil under cyclic and monotonic loads is of great importance in the safe design of mechanically stabilized earth walls. In this article, the method of conducting a multistage pullout (MSP) test on the polymeric strip (PS) is presented. The post-cyclic behavior of the reinforcement can be evaluated using a large-scale pullout apparatus adopting MSP test and one-stage pullout (OSP) test procedures. This research investigates the effects of various factors including load amplitude, load frequency, number of load cycles and vertical effective stress on the peak apparent coefficient of friction mobilized at the soil-PS interface and the pullout resistance of the PS buried in dry sandy soil. The results illustrate that changing the cyclic tensile load frequency from 0.1 Hz to 0.5 Hz does not affect the pullout resistance. Moreover, the influence of increasing the number of load cycles from 30 to 250 on the peak pullout resistance is negligible. Finally, the effect of increasing the cyclic tensile load amplitude from 20% to 40% on the monotonic pullout resistance can be ignored. The peak apparent coefficient of friction mobilized at the soil-PS interface under monotonic and cyclic load conditions decreases with the increase in vertical effective stress.
Keywords
Related Topics
Physical Sciences and Engineering Earth and Planetary Sciences Geotechnical Engineering and Engineering Geology
Authors
, , ,