Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
11032998 | Thermal Science and Engineering Progress | 2018 | 11 Pages |
Abstract
The objective of the present work is to investigate energetically and financially a solar assisted heating system for various building envelopes in the climate conditions of Greece. The examined solar heating system includes flat plate collectors, storage tank, boiler and heating devices. The analysis is conducted for the locations of Athens and Thessaloniki which are the most populated cities in Greece. The total analysis is conducted with the TEE-KENAK software which is the official software of Greece for energy audit studies. Different insulation thicknesses are examined (from 0â¯cm up to 8â¯cm) and three different glazing scenarios are also investigated. The collecting area is studies from 0â¯m2 up to 30â¯m2 for all the building scenarios. The results are evaluated energetically and financially. The optimum design scenarios are determined using the net present cost criterion, as well as through a multi-objective optimization/evaluation procedure. Finally, it is found that the optimum design for Athens is the use of 6â¯cm insulation layer, double glazing (G2 quality) and 30â¯m2 solar collectors, while the optimum scenario for Thessaloniki is the use of 8â¯cm insulation layer, coated glazing (G3 quality) and 30â¯m2 solar collectors. The results of this work can be applied for the proper design of the Greek buildings regarding the new buildings and the retrofitting cases.
Related Topics
Physical Sciences and Engineering
Energy
Energy Engineering and Power Technology
Authors
Georgios Mitsopoulos, Evangelos Bellos, Christos Tzivanidis,