Article ID Journal Published Year Pages File Type
1198967 Journal of Chromatography A 2016 10 Pages PDF
Abstract

•Proof-of-principle of a pH-gradient SMB process for the purification of antibody fragments.•SMB design was based on pH-gradient batch elution experiments.•The pH-gradient SMB process outperformed equivalent batch process.

This paper deals with the theoretical design and experimental validation of an affinity-based continuous multi-column chromatography process for the purification of single-chain Fragment variable (scFv) antibodies. An open-loop 3-zone pH-gradient simulated moving bed (SMB) process was investigated exploiting the highly specific affinity of metal ions toward histidine-tagged recombinant proteins. The separation problem was simplified by considering the cell culture supernatant as a pseudo-binary mixture. The influence of mobile phase pH on the adsorption isotherm parameters was estimated by the inverse method using recorded pH-gradient batch elution profiles. Suitable operating parameters for the SMB process were identified using an equilibrium stage model and subsequently validated in a lab-scale SMB unit. Finally, the performance of the pH-gradient SMB process was compared against a non-optimized batch process. Biologically active single-chain Fragment variable antibody formats were purified continuously with 9% more recovery, 11 times more productivity (576 mg of purified scFv per day and liter stationary phase in SMB) and enriched by a factor of 2.5 compared to those obtained in the non-optimized batch process.

Related Topics
Physical Sciences and Engineering Chemistry Analytical Chemistry
Authors
, ,