Article ID Journal Published Year Pages File Type
1206606 Journal of Chromatography A 2012 5 Pages PDF
Abstract

The enantiomeric separation of albendazole sulfoxide was carried out by simulated moving bed chromatography with variable zones (VARICOL). An overall recovery of 97% was achieved and enantiomeric ratios of 99.5% for raffinate and 99.0% for extract were attained. A total of 880 mg of (+)-albendazol sulfoxide and 930 mg of its antipode were collected after 55 cycles or 11 h of process, resulting in a mass rate of 2 g/day. Furthermore the absolute configuration of the enantiopure compounds was determined for the first time by vibrational circular dichroism (VCD) with the aid of theoretical calculations as (−)-(S) and (+)-(R)-albendazole sulfoxide.

► Isolation of albendazole sulfoxide enantiomers by VARICOL process. ► High purities of enantiomers were achieved with a 100% methanol as eluent. ► Solvent re-usage resulting in low discard volumes was an important achievement. ► (−)-(S) and (+)-(R)-albendazole sulfoxide determined by VCD and DFT calculations.

Related Topics
Physical Sciences and Engineering Chemistry Analytical Chemistry
Authors
, , , , , , ,