Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
1209035 | Journal of Chromatography A | 2007 | 8 Pages |
Abstract
LC–NMR utilizing 1H and 29Si NMR spectroscopy is ideally suited for the analysis of silicones. It is shown that reversed phase gradient LC–NMR surpasses standard gel permeation chromatography (GPC) and diffusion ordered spectroscopy (DOSY) in the analysis of model hydride terminated polydimethylsiloxane. 1H and 29Si NMR in the stopped-flow arrangement leads to full identification of the components. Concentration gradient introduces a dependence of the 29Si shifts on solvent composition, this dependence can be substantially reduced by a proposed method of referencing. It is shown that the ADEQUATE version of powerful but insensitive 2D INADEQUATE experiment can be used for complete line assignment.
Keywords
Related Topics
Physical Sciences and Engineering
Chemistry
Analytical Chemistry
Authors
Vratislav Blechta, Milan Kurfürst, Jan Sýkora, Jan Schraml,