Article ID Journal Published Year Pages File Type
1209955 Journal of Chromatography A 2006 4 Pages PDF
Abstract

In this paper, a monolithic ODS-silica gel column dynamically coated with cetylpyridinium chloride (CPC) was used to demonstrate the high-speed and efficient separation of zonisamide (1,2-benzisoxazole-3-methanesulfonamide, ZNS), its raw material (1,2-benzisoxazole-3-methanecarbonic acid) and intermediate (sodium 1,2-benzisoxazole-3-methanesulfonate) in drugs. Using a 40 mmol/L sodium perchlorate solution (pH 7.0) containing 10% acetonitrile as eluent, the analytes were eluted with a sharp and symmetrical peak within 3.0 min, detected with UV detection at 210 nm. The column demonstrates excellent stability over time, and exhibits unusual selectivity for pharmaceutical analysis. Thus, by this developed method, zonisamide in drug samples can be determined rapidly with high recoveries and good selectivity.

Related Topics
Physical Sciences and Engineering Chemistry Analytical Chemistry
Authors
, , ,