Abstract

A highly sensitive HPLC–ESI-MS method has been developed and validated for the quantification of ginkgolic acid (15:1) in a small quantity of rat plasma (50 μL) using its homologous compound ginkgolic acid (17:1) as an internal standard. GA (15:1) and GA (17:1) were extracted from biological matrix by direct protein precipitation with 5-fold volume of methanol and separated on an Elite hypersil BDS C18 column (2.1 × 100 mm, 3 μm), eluted with acetonitrile:water (92:8, v/v, containing 0.3% glacial acetic acid). Linear range was 8–1000 ng/mL with the square regression coefficient (r2) of 0.996. The lowest concentration (8 ng/mL) in the calibration curve was estimated as LLOQ with both deviation of accuracy and RSD of precision <20% (n = 6). The intra- and inter-day precision ranged from 3.6% to 9.9%, and the intra- and inter-day accuracy was between 89.9% and 101.3%. This method was successfully applied to study pharmacokinetics of GA (15:1) in rats after oral administration at a dose of 10 mg/kg. GA (15:1) pharmacokinetic parameters Cmax, Tmax, t1/2, AUC0–12h are 1552.9 ± 241.0 ng/mL, 0.9 ± 0.7 h, 5.5 ± 2.6 h, 3356.0 ± 795.3 ng h/mL, respectively.