To evaluate the penetration of the blood–brain barrier by 9-fluoropropyl-(+)-dihydrotetrabenazine (AV-133), microdialysis probes were implanted simultaneously into rat blood and brain, and a liquid chromatography–tandem mass spectrometric method was developed and validated to monitor the AV-133 concentration in the microdialysates. The chromatographic separation was performed on an XTerra C18 column (150 mm × 2.1 mm i.d., 5 μm particles) with gradient elution. The mass spectrometer was operated in positive mode using electrospray ionization. The analytes were measured using the multiple-reaction-monitoring mode. The calibration curves were linear over the range of 5.00–1000 ng/mL AV-133, with a coefficient of determination >0.995. The accuracies ranged from 99.5% to 105.0% and the precisions were <10% for AV-133. This method was used to determine the concentrations of AV-133 and its pharmacokinetics in the brains and blood of rats. The blood and brain concentration–time profiles for AV-133 were obtained, and the blood–brain barrier penetration was evaluated.