Article ID Journal Published Year Pages File Type
1215385 Journal of Chromatography B 2007 7 Pages PDF
Abstract

This paper evaluates the immunopurification behavior of a plantibody HBsAg specific plantibody coupled to Sepharose CL-4B at different ligand densities. Results show no significant differences in the adsorption and elution capacities, and rHBsAg recovery of immunosorbents at 3.43, 4.45, and 5.31 mg/mL of ligand densities compared to its mouse-derived mAb counterpart consistently used in the rHBsAg purification process. Therefore, plantibody ligand densities higher than 3.43 mg/mL do not improve the immunopurification behavior of this immunosorbent, but increase the antibody consumption and the Hepatitis B vaccine cost. Immunosorbent of 2.23 mg/mL of ligand density demonstrated a poor performance. The IgG leached detectable level never exceeded the approved limit (3 ng IgG/μg rHBsAg). Values close to this limit were only observed at the ligand density of 5.31 and 2.27 mg/mL. In the case of the ligand density of 2.23 mg/mL the IgG leached value was high (2.90 ng IgG/μg rHBsAg) due to a low level of eluted antigen. In conclusion, it supports feasibility of using this plantibody at 3.43 mg/mL of ligand density for large-scale immunopurification of rHBsAg for human use, avoiding the biosafety and ethical concerns of the massive use of animals for this purpose.

Related Topics
Physical Sciences and Engineering Chemistry Analytical Chemistry
Authors
, , , , , , , , , , , , , , ,