Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
1216674 | Journal of Chromatography B | 2006 | 7 Pages |
A fast liquid chromatographic assay with mass spectrometric detection (LC/MS) has been developed and validated for the simultaneous determination of methadone (MT), its primary metabolite, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP) and alprazolam, in human plasma. The extraction procedure was performed with automatic solid phase extraction, and the compounds were separated with a Sunfire® column using a gradient mode. Deuterated analogues for all of the analytes of interest were used for quantitation. Limits of detection (LOD) were established between 0.5 and 1 ng/ml. Linearity was obtained over a range of 2–2000 ng/ml with an average correlation coefficient (R2) of >0.99. Intra- and inter-batch coefficients of variation and relative mean errors were less than 10% for all analytes and concentrations. The recoveries were higher than 50.0% in all cases. The method proved to be suitable for evaluation of plasma obtained from patients enrolled in a MT-maintenance program who are frequently treated with alprazolam as a sedative.