Abstract

Voriconazole is a widely used triazole antifungal agent with a broad spectrum including Aspergillus species. A simple, sensitive and selective high-performance liquid chromatography method for the determination of voriconazole in human plasma and saliva was developed. Drug and internal standard (UK-115 794) were extracted from alkaline plasma and saliva with n-hexane–ethyl acetate (3:1, v/v) and analyzed on a Luna C 18 column with fluorimetric detection set at excitation and emission wavelengths of 254 and 372 nm, respectively. The calibration curve was linear through the range of 0.1–10 μg/ml using a 0.3 ml sample volume. The intra- and inter-day precisions were all below 6.1% for plasma and below 9.1% for saliva. Accuracies ranged from 94 to 109% for both matrices. Mean recovery was 86 ± 4% for voriconazole. The method showed acceptable values for precision, recovery and sensitivity and is well suited for routine analysis work and for pharmacokinetic studies.