| Article ID | Journal | Published Year | Pages | File Type | 
|---|---|---|---|---|
| 1217000 | Journal of Chromatography B | 2008 | 4 Pages | 
Abstract
												A quick, precise and reliable HPLC method has been developed to determine tripterin in rat plasma. After liquid–liquid extraction, the analytes was analyzed on a Discovery ODS C18 column (5 μm, 4.6 mm × 250 mm) with an isocratic elution consisting of methanol–water–phosphoric acid (87:13:0.2, v/v/v). Ultraviolet detection was at 425 nm. Using trioxymethylanthraquinone as an internal standard, the assay was linear over the concentration range of 0.025–1.60 μg/mL (r2 = 0.9988). The extraction recovery of tripterin in rat plasma was more than 62%. The intra- and inter-day precision was less than 13% (CV). This validated method was successfully applied to the pharmacokinetics of tripterin in rats.
Keywords
												
											Related Topics
												
													Physical Sciences and Engineering
													Chemistry
													Analytical Chemistry
												
											Authors
												Wenyan Wang, Ke Liu, Hongwei Dong, Wanhui Liu, 
											