Article ID Journal Published Year Pages File Type
1218179 Journal of Food Composition and Analysis 2016 7 Pages PDF
Abstract

•An extraction method to isolate 10 phenolic acids by IP-DLLME-SFO was developed.•10 phenolic acids were separated within 40 min by using a core–shell particle column.•Ion pairing reagent facilitated efficiency of phenolic acids extraction from wine.•This method is more sensitive and rapid than previous methods.

This study describes a novel sample preparation method for extraction of phenolic acids from wine using ion pair dispersive liquid–liquid microextraction based on the solidification of a floating organic droplet (IP-DLLME-SFO). The ion-pairing technique combined with DLLME-SFO dramatically enhanced the extraction efficiency for very polar phenolic acids, such as gallic acid and protocatechuic acid, which could not be extracted by DLLME-SFO in the absence of an ion-pairing reagent. The effects of the parameters that can affect the extraction efficiency were systematically investigated, including the type and concentration of ion-pairing reagent, type and volume of extraction and dispersive solvents, extraction time, sample pH, and ion strength. The method linearity was constructed in the range of 0.01–15 μg/mL, and the sensitivity expressed as limit of detection was as low as 10 ng/mL. The method that we developed was applied for the analysis of commercial wine samples, revealing different levels of phenolic acids among these products.

Graphical abstractFigure optionsDownload full-size imageDownload as PowerPoint slide

Related Topics
Physical Sciences and Engineering Chemistry Analytical Chemistry
Authors
, , , , , ,