Abstract
A simple and sensitive reverse phase ultra fast liquid chromatographic (UFLC) method for simultaneous determination of nitrendipine and carvone in skin diffusate samples and microemulsions was developed and validated. The separation was achieved using a gradient mobile phase, on an Onyx column. The eluents were monitored by photodiode array detection. The linearity ranges of proposed method were 0.125-50 μg mL−1 and 0.125-30 μg mL−1 for nitrendipine and carvone respectively. The intra-day and inter-day coefficient of variation and percent error values of the assay method were less than 10%. The method was found to be precise, accurate, and specific during the study. The method was successfully applied for simultaneous estimation of nitrendipine and carvone in ex vivo skin diffusate samples and microemulsions.