Article ID Journal Published Year Pages File Type
1223873 Journal of Pharmaceutical and Biomedical Analysis 2008 6 Pages PDF
Abstract

A UPLC–MS method for determining Coenzyme Q10 (CoQ10) levels in rat serum was developed. CoQ10 was quantitatively extracted into 2-propanol using a fast extraction procedure. The separation of CoQ10 was performed on a Waters Acquity UPLC™ BEH C18 column (1.7 μm, 1.0 mm × 50 mm) with the mobile phase containing acetonitrile, 2-propanol, and formic acid (90:10:0.1) over 5 min. The sensitivity of this method allows for the quantitation of 50 ng/mL CoQ10 in serum (S/N = 10). The linearity of this method was found to be from 50 to 20,000 ng/mL. The precision was less than 10% (intra- and inter-day), and the average extraction recovery was between 90 and 105%. This procedure provides a precise, sensitive and direct assay method for the determination of CoQ10 in rat serum after oral administration. This method could be applied to further pharmacokinetic studies of CoQ10.

Related Topics
Physical Sciences and Engineering Chemistry Analytical Chemistry