Abstract
The chiral separation of a new antianginal agent has been investigated on a chiral cellulose column with UV and circular dichroism (CD) detection. This benzoxathiepin derivative under development has two stereogenic centers whose (R,S) stereoisomer shows an interesting antianginal activity. After optimisation of the mobile phase composition, a baseline-resolved separation of the four stereoisomers was achieved on a Chiralcel OJ-H chiral column by using methanol–ethanol–diethylamine (25:75:0.1, v/v/v) as mobile phase. The CD detection system allowed quantitation and a linear response was observed within a 10–200 μg mL−1 concentration range (r2 = 0.9966) and limit of quantification down to 2 μg mL−1 was achieved.
Related Topics
Physical Sciences and Engineering
Chemistry
Analytical Chemistry
Authors
Martine Beaufour, Philippe Morin, Jean-Paul Ribet, Jean-Claude Maurizot,