Article ID Journal Published Year Pages File Type
1227925 Microchemical Journal 2010 7 Pages PDF
Abstract
Greater sampling efficiency was obtained with liquid argon as freezing fluid and air flow rate of 150 mL min− 1 for two hours. Best results have been obtained with preconcentration for 3 min and injection volume of 3 ml. For H2S, CH3SH and CH3S2CH3 the method showed a precision of 89%, limit of detection of 0.10 µg m− 3 and limit of quantification 0.3 µg m− 3. For CH3SCH3 and CS2 the corresponding values were 89%, 0.15 µg m− 3 and 0.5 µg m− 3 and for COS were 75%, 0.18 µg m− 3 and 0.8 µg m− 3 respectively. Sampling efficiency varied between 70-80% for all the RSCs. Accuracy of H2S from field measurements obtained with parallel measurements using a continuous monitor varied between 88 and 98%. The optimized methodology proved to be suitable for field measurements in urban tropical atmospheres with different characteristics.
Related Topics
Physical Sciences and Engineering Chemistry Analytical Chemistry
Authors
, , , , ,