Article ID Journal Published Year Pages File Type
1240597 Spectrochimica Acta Part B: Atomic Spectroscopy 2007 6 Pages PDF
Abstract
In this work is presented a new approach to determine the crater volume based on a numerical model which calculates the crater volume from a 2D profile. Eight craters were made in a stainless steel at different experimental conditions (to obtain varied crater shapes) and the values offered by the model (a computer software) were compared with those obtained using an optical profilometer. The discrepancy between methods is lower than 15%. Moreover, 68 crater volumes were calculated by using a mathematical approximation to the crater profile (fitting it by analytical functions and integrating) and were compared with those reported by the numerical model, giving rise to discrepancies below than 5% in most cases.
Related Topics
Physical Sciences and Engineering Chemistry Analytical Chemistry
Authors
, , , , ,