Article ID Journal Published Year Pages File Type
1241442 Spectrochimica Acta Part B: Atomic Spectroscopy 2007 7 Pages PDF
Abstract
A neutron-activated Al2O3 powder SRM 699 (NIST) containing the γ-radiation emitting radionuclides 51Cr, 59Fe, 60Co and 65Zn has been used to study the influence of thermochemical reagents on the volatilization and transport efficiency for these trace elements in electrothermal vaporization inductively coupled plasma mass spectrometry (ETV-ICP-MS) of Al2O3 powders. From the signals in the γ-spectra for the radiotracers it has been found that less than 2% of the elements Cr, Fe, Co and Zn is left back in a graphite furnace from Al2O3 powders at 2200 °C even without addition of a thermochemical reagent and the latter even was found to decrease the volatilization efficiencies. The recovery for the radiotracers on filters at the end of the transport tube as measured from the signals in the γ-spectra, however, was found to increase in most cases (i.e. from about 10% to more than 20%) when Pd(NO3)2, Pd(NO3)2 + Mg(NO3)2, PdCl2, IrCl3, SnCl2, AgCl, NaF, NH4Cl and NH4F were added at amounts generally used in electrothermal vaporization inductively coupled plasma mass spectrometry. However, when adding higher amounts as stoichiometrically required for a complete halogenation of the sample matrix in the case of AgCl, C8F15O2Na, IrCl3 or PdCl2 the transport efficiencies considerably decrease again. As shown in the case of NH4Cl the amount of thermochemical reagent used has to be optimized so as to obtain maximum analyte transport efficiencies. A comparison of the influence of NH4Cl on the transport efficiencies with its influence on the ETV-ICP-MS signals for Fe demonstrates the importance of transport efficiency changes for the effects of thermochemical reagents in electrothermal vaporization inductively coupled plasma mass spectrometry.
Related Topics
Physical Sciences and Engineering Chemistry Analytical Chemistry
Authors
, , ,