Article ID Journal Published Year Pages File Type
1241939 Talanta 2015 4 Pages PDF
Abstract

•An ultrasound assisted-deep eutectic solvent extraction procedure was developed.•Ultrasound assisted-deep eutectic solvent extraction system is green.•NIST SRM 1577b bovine liver CRM was used in the optimization.•The method was applied to the determination of iron in liver samples.

A green, novel and effective ultrasound assisted-deep eutectic solvent (DES) extraction (UA-DES-E) procedure was developed for extraction of iron from sheep, bovine and chicken liver samples. The analytical parameters including type and composition DES, volume of DES, ultrasonication time and ratio of sample to DES were optimized by using 50 mg of the NIST SRM 1577b bovine liver certified reference material. The limit of detection (LOD) and the limit of quantification (LOQ) were found as 0.026 µg mL−1 and 0.085 µg mL−1, respectively. The relative standard deviation (RSD) as a result of 7 replicates of 50 mg of certified reference material was 1.4%. The accuracy of proposed method was checked by the addition/recovery tests to NIST SRM 1577b bovine liver and a sheep liver. The extraction method was applied to extraction of iron from bovine, sheep and chicken liver samples retail from markets at Kayseri, Turkey with satisfactory results (recoveries higher than 95%).

Graphical abstractFigure optionsDownload full-size imageDownload as PowerPoint slide

Related Topics
Physical Sciences and Engineering Chemistry Analytical Chemistry
Authors
, ,