Article ID Journal Published Year Pages File Type
1243833 Talanta 2016 5 Pages PDF
Abstract

•First sequential injection IR determination of petroleum products (PP) in water.•On-site PP extraction during water sampling.•Design of a PTFE cartridge for PP extraction.

The simple and easy performed automated method for the IR determination of petroleum products (PP) in water using extraction-chromatographic cartridges has been developed. The method assumes two stages: on-site extraction of PP during a sampling by using extraction-chromatographic cartridges and subsequent determination of the extracted PP using sequential injection analysis (SIA) with IR detection. The appropriate experimental conditions for extraction of the dissolved in water PP and for automated SIA procedure were investigated. The calibration plot constructed using the developed procedure was linear in the range of 3–200 μg L−1. The limit of detection (LOD), calculated from a blank test based on 3σ was 1 µg L−1. The sample volume was 1 L. The system throughput was found to be 12 h−1.

Graphical abstractFigure optionsDownload full-size imageDownload as PowerPoint slide

Related Topics
Physical Sciences and Engineering Chemistry Analytical Chemistry
Authors
, , , , , , ,