A feasible three-step method for ochratoxin A (OTA) rapid detection was developed and applied for OTA screening in high-coloured matrices such as liquorice, ginger, nutmeg, black pepper, white pepper and Capsicum spp. spices at a control level of 10 μg kg−1. The method was based on the clean-up tandem immunoassay column and involved three steps: extract application, washing step and application of chromogenic substrate. A significant simplification of the assay was reached by using an additional frit with conjugate inside the clean-up tandem immunoassay column. The time for analysis was less than 10 min, including 5 min for colour development. Results were visually evaluated as colour development for negative result or no colour development for positive result. The method was coupled with a simple methanol-based extraction. A total of 27 samples were screened for OTA with the proposed method. It was shown that two samples of red pepper and one sample of liquorice, pili-pili, chilli and cayenne were contaminated with OTA above the control level at 10 μg kg−1, but none of tested ginger, nutmeg, black pepper and white pepper.