Article ID Journal Published Year Pages File Type
1246142 Talanta 2007 5 Pages PDF
Abstract

A system for determination of manganese, after preconcentration with 3% (w/w) 1-(2-pyridylazo)-2-naphthol (PAN), adsorbed on microcrystalline naphthalene is proposed. An amount of 200 mg of this complexing mixture is placed in a glass column and conditioned with a NH4Cl/NH4OH buffer solution (pH 9.5). The aqueous sample, containing manganese, is treated with an ammonium tartrate solution, then with a hydroxylammonium chloride solution and, finally, with a buffer solution. The resulting solution is passed through the column containing microcrystalline naphthalene modified with 1-(2-pyridylazo)-2-naphthol (PAN) where Mn(II) is retained. The column is first washed with deionized water and then with 10.0 ml of dimethylformamide to dissolve the Mn(II)–PAN/naphthalene complex. Manganese is determined by air–acetylene flame atomic absorption spectrometry. About 1 μg of manganese can be concentrated from 200 ml of aqueous sample, allowing a preconcentration factor of 20, a limit of quantification of 5 ng ml−1 and R.S.D. of 3.8%. The accuracy was ascertained using certified reference materials, including samples of urine and glass. Water samples were also analysed and the results are in good agreement with those obtained by graphite furnace atomic absorption spectrometry.

Related Topics
Physical Sciences and Engineering Chemistry Analytical Chemistry
Authors
, , , ,