Article ID Journal Published Year Pages File Type
1428937 Materials Science and Engineering: C 2012 11 Pages PDF
Abstract

(Ti, O)/Ti, (Ti, N)/Ti and (Ti, O, N)/Ti composite coatings were fabricated on NiTi shape memory alloy via plasma immersion ion implantation and deposition (PIIID). Surface morphology of samples was investigated using atomic force microscopy (AFM) and scanning electron microscopy (SEM). Cross-sectional morphology indicated that the PIIID-formed coatings were dense and uniform. X-ray diffraction (XRD) was used to characterize the phase composition of samples. X-ray photoelectron spectroscopy (XPS) results showed that the surface of coated NiTi SMA samples was Ni-free. Nanoindentation measurements and pin-on-disc tests were carried out to evaluate mechanical properties and wear resistance of coated NiTi SMA, respectively. For the in vitro biological assessment of the composite coatings in terms of cell morphology and cell viability, osteoblast-like SaOS-2 cells and breast cancer MCF-7 cells were cultured on NiTi SMA samples, respectively. SaOS-2 cells attached and spread better on coated NiTi SMA. Viability of MCF-7 cells showed that the PIIID-formed composite coatings were noncytotoxic and coated samples were more biocompatible than uncoated samples.

► PIIID-formed coatings were fabricated on NiTi SMA to improve its biocompatibility. ► Microstructure, mechanical properties and biocompatibility of coatings were investigated. ► All PIIID-formed composite coatings were noncytotoxic and cytocompatible.

Related Topics
Physical Sciences and Engineering Materials Science Biomaterials
Authors
, , , , ,