Article ID Journal Published Year Pages File Type
1429407 Materials Science and Engineering: C 2013 9 Pages PDF
Abstract

Hydroxyapatite (HAp) coatings were prepared on 316L stainless steel (316LSS) substrates by electrochemical deposition in the solutions containing Ca(NO3)2·4H2O and NH4H2PO4 at different electrolyte concentrations. Along with the effect of precursor concentration, the influence of temperature and H2O2 content on the morphology, structure and composition of the coating was thoroughly discussed with the help of X-ray diffraction (XRD), Scanning electron microscopy (SEM), Fourier transform infrared (FTIR) spectra. The in vitro tests in simulated body fluids (SBF) were carried out and then the morphological and structural changes were estimated by SEM and electrochemical techniques (open circuit potential, polarization curves, Nyquist and Bode spectra measurements). Being simple and cost-effective, this method is advantageous for producing HAp implant materials with good properties/characteristics, aiming towards in vivo biomedical applications.

► Successful electrodeposition of HAp on 316L SS by a simple method ► The influence of some key parameters on the HAP morphology was discussed. ► Morphological and structural changes of HAP layer in SBF were thoroughly investigated.

Related Topics
Physical Sciences and Engineering Materials Science Biomaterials
Authors
, , , , , , ,