Article ID Journal Published Year Pages File Type
1431152 Materials Science and Engineering: C 2006 6 Pages PDF
Abstract

In this study, the effect of cold working on the recrystallization and thermal oxidation behaviours of Grade 2 quality commercial purity titanium (CP-Ti) were examined. Recrystallization tests were carried out on the 23%, 35% and 50% cold worked samples at various temperatures in between 550 and 700 °C. Thermal oxidation of the cold worked samples was conducted at 600 and 650 °C. Recrystallization activation energy was calculated as 66–88 kJ/mol. Since thermal oxidation progresses by oxide layer growth and diffusion of oxygen into the substrate (oxygen diffusion zone formation), oxygen diffusion zone formation activation energies of 149–170 kJ/mol were calculated for the examined cold work ratios. These results indicate that when a cold worked CP-Ti was subjected to thermal oxidation treatment to improve its surface hardness and wear resistance, it loses its bulk hardness due to recrystallization.

Related Topics
Physical Sciences and Engineering Materials Science Biomaterials
Authors
, , ,