Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
1466773 | Composites Part A: Applied Science and Manufacturing | 2012 | 10 Pages |
Abstract
This paper presents experimental observations from the filling and post-filling stages of 1D axisymmetric Resin Infusion (VARTM) and RTM Light. A series of experiments have been performed to investigate the influence of mould flexural stiffness and fill mode on fluid pressure, cavity thickness, filling stage time, and post-filling stage time. Observations are also made on the effect of those parameters on the repeatability of nominally identical experiments. This paper helps identify the circumstances where a RTM simulation would be sufficiently accurate for an RTM Light process, and consequently where a full flexible tooling simulation is necessary.
Related Topics
Physical Sciences and Engineering
Materials Science
Ceramics and Composites
Authors
J. Timms, S. Bickerton, P.A. Kelly,