Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
1470890 | Corrosion Science | 2009 | 4 Pages |
Abstract
Time of Flight-Secondary Ion Mass Spectrometry (ToF-SIMS) was used to examine the film formed on pure magnesium by immersion for 2 min in ultra pure water. The ToF-SIMS data indicates that there is magnesium hydride within the surface film. The presence of MgH2 is a result of the Mg corrosion mechanism.
Keywords
Related Topics
Physical Sciences and Engineering
Materials Science
Ceramics and Composites
Authors
Antoine Seyeux, Ming Liu, Patrik Schmutz, Guangling Song, Andrej Atrens, Philippe Marcus,