Abstract

The effect of residual stresses on electrochemical permeation in iron membrane was investigated. Four thermal and mechanical treatments were chosen to obtain different surface states in relation to the residual stresses.Residual stresses were determined by X-ray diffraction (XRD) using the Macherauch and Müller method. The results were completed by the microhardness measurements. For all iron membranes, compressive residual stresses were obtained.Electrochemical permeation experiments using a Devanathan and Stachurski cell were employed to determine the hydrogen permeation behaviour of the various iron membranes. The latter was charged with hydrogen by galvanostatic cathodic polarization in 0.1 M NaOH at 25 °C. The experimental results revealed that hydrogen permeation rate increases with increasing residual stresses introduced in iron membranes.