Article ID Journal Published Year Pages File Type
1472836 Corrosion Science 2011 11 Pages PDF
Abstract

The effect of temperature on the cathodic protection criteria of a pipeline steel under insulation was studied in the temperature range 25–95°C in synthetic ground water. Sufficient protection could not be obtained at −0.85 VCSE at elevated temperatures, while more negative potential than −0.85 VCSE was required to obtain satisfactory protection. The anodic Tafel lines were used to determine the protection potential at each temperature. The protection potential was shifted to the more negative value as the temperature increased. The most negative potential was measured at 80°C, which decreased to −1.346 VSCE. Acceptable corrosion rates were achieved when the potential was held at −1.346 VSCE over the temperature range studied.

Related Topics
Physical Sciences and Engineering Materials Science Ceramics and Composites
Authors
, ,