Article ID Journal Published Year Pages File Type
1490829 Materials Research Bulletin 2010 5 Pages PDF
Abstract

This paper reports the effects of processing densification on the mechanical properties of hydroxyapatite bioceramics. Densification of synthetic hydroxyapatite is conducted in the range 1000–1300 °C. X-ray diffraction and SEM microscopy are used to check the microstructure transformations. Vickers hardness, toughness and Young's modulus are analyzed versus the density and grain size. The sintering temperature and the particle size influence strongly the densification and the resulting mechanical properties. In addition, the critical sintering temperature appears around 1200 °C and the declined strength at the temperature up to 1200 °C is found sensitive to the dehydroxylation process of hydroxyapatite.

Related Topics
Physical Sciences and Engineering Materials Science Ceramics and Composites