Abstract
In the present work, the heat exchanger is numerically simulated for the steady state conditions and the results are validated against the experimental data available from the literature. The area correction factor is identified for the calculation of effective heat transfer area which takes into account the effect of helical geometry. In order to get an optimum performance of the cryocoolers, operating parameters like mass flow rate, pressure and design parameters like heat exchanger length, helical diameter of coil, fin dimensions, fin density have to be identified. The present work systematically addresses this aspect of design for miniature J-T cryocooler.