Article ID Journal Published Year Pages File Type
1507584 Cryogenics 2012 5 Pages PDF
Abstract
► A pump system composed of an MgB2 motor and MgB2 level sensors was constructed. ► The centrifugal pump was formed by attaching an aluminum impeller to the motor. ► A glass Dewar vessel receives the liquid hydrogen from a cryostat for the pump. ► The MgB2 sensors were used to detect the liquid level and to control the motor. ► Transfer of liquid hydrogen was successfully carried out with the pump system.
Related Topics
Physical Sciences and Engineering Materials Science Electronic, Optical and Magnetic Materials
Authors
, , , , , , , , , , , , ,