Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
1508545 | Cryogenics | 2006 | 6 Pages |
Abstract
For the development of electrical insulation design of a HTS transformer with Z continuous winding, we have discussed insulation composition and investigated breakdown characteristics such as breakdown of LN2, polymer and surface flashover on FRP and breakdown-surface combination in LN2. Also we have designed and manufactured a bobbin that has spiral slot for the Z continuous winding. A Z continuous winding mini-model from Kapton film insulated Cu tape for simulated 22.9 kV class HTS transformer has been constructed using 0.1% breakdown strength obtained by Weibull distribution. The winding model was measured with respect to its insulation characteristics such as ac (50 kV, 1 min) and impulse (154 kV, 1.2 Ã 50 μs full wave, 3 times) withstand test and its excellent performance was confirmed.
Related Topics
Physical Sciences and Engineering
Materials Science
Electronic, Optical and Magnetic Materials
Authors
Seung-Myeong Baek, Jun Lee, Hyeon-Gweon Cheon, Mun-Soo Yun, Hyun-Hee Kim, Sang-Hyun Kim,