| Article ID | Journal | Published Year | Pages | File Type |
|---|---|---|---|---|
| 1508921 | Energy Procedia | 2016 | 8 Pages |
Abstract
The target of this work is to evaluate three analytical techniques, ICP-MS, SEM-EDS and XRD, which can be applied in corrosion monitoring of ethanolamine based post-combustion CO2 capture plants. The work is based on analyses of the solvent and 316 SS cylinders used in thermal degradation experiments. ICP-MS is used for the determination of total Fe, Cr and Ni of the solutions as an indication of corrosivity. Additionally, the cylinder surface was examined with SEM-EDS and XRD was used for the identification of corrosion products. Finally, a discussion is given on the various techniques, their limitations and advantages.
Related Topics
Physical Sciences and Engineering
Energy
Energy (General)