Article ID Journal Published Year Pages File Type
1514336 Energy Procedia 2011 7 Pages PDF
Abstract

Building integrated photovoltaic is an art and trend using PV module to replace building material on the outer wall. The semi-transparent c-Si PV module is installed to replace the tiled roof in this study. PV power generation prediction is follow with module performance, installation site and meteorological data. A simple model is created to simulate the power output using PV module thermal model. PV module thermal model is the relation of the module temperature, ambient temperature and solar radiation. In the present study, two parameter linearly regression model is to simulate the power generation in BIPV system. The monthly root-mean -square error (RMSE) is about 4.7%.