Article ID Journal Published Year Pages File Type
1514896 Energy Procedia 2011 8 Pages PDF
Abstract
Through detailed optimisation studies, it is concluded that 3 SG per loop with each having 433 tubes of 30 m long, 12.6 mm ID and 2.4 mm wall thickness for a design life of 60 years provides economical configuration leading to a saving of ∼25% in total cost. Further, enhanced safety is ensured by reduction of ∼40% tube to tube-sheet joints as compared with PFBR SG.
Related Topics
Physical Sciences and Engineering Energy Energy (General)