Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
1548851 | Progress in Natural Science: Materials International | 2009 | 5 Pages |
Abstract
An optimal assessment method for the design of accelerograph arrays to monitor the seismic response of high-rise buildings is presented. This method uses a finite element model of the structure based on a simplified multi-degree-of-freedom system model defined using the parameter identification method. The off-diagonal element of the Modal Assurance Criterion (MAC) matrix of mode is taken as the target function in order to facilitate the selection of optimum locations. An example for a high-rise building in Dalian indicates that a minimum of 15 locations provide the optimum sites for monitoring the dynamic response of the selected building in view of economic benefit.
Related Topics
Physical Sciences and Engineering
Materials Science
Electronic, Optical and Magnetic Materials
Authors
Guoxin Wang, Weizheng Wang, Katayoun B. Aafshar, Dragi Dojcinovski,