Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
1550251 | Solar Energy | 2013 | 9 Pages |
•An organic Rankine cycle with ejector (EORC) and a double organic Rankine cycle (DORC) are introduced.•The analysis of exergy loss in each component of the EORC, DORC and ORC and the comparison are conducted.•The exergy efficiency of the cycles can be ranked from high to low: DORC > EORC > ORC.
In consideration of the low efficiency of the organic Rankine cycle (ORC) with low-grade heat source (LGHS), an organic Rankine cycle with ejector (EORC) and a double organic Rankine cycle (DORC) based on the ORC is introduced in this paper. The thermodynamic first law and second law analysis and comparison on the ORC, EORC and DORC cycles are conducted on the cycle’s power output, thermal efficiency, exergy loss and exergy efficiency. Water is chosen as the LGHS fluid, and the same temperature and mass flow rate of the water is the standard condition for the comparative analysis on the cycles. The emphasis is on the thermodynamic performance at the maximum net power output of the cycles. The results show the power output is higher in the EORC and DORC compared to the ORC. And the cycle’s exergy efficiency could be ranked from high to low: DORC > EORC > ORC.