Article ID Journal Published Year Pages File Type
1558683 Procedia Structural Integrity 2016 8 Pages PDF
Abstract

Peel tests were performed on pharmaceutical drug patches which consisted of a polyester backing membrane supporting an acrylic pressure-sensitive adhesive (PSA) (without and with an anti-fungal drug present) adhered to a polyethylene substrate. Interfacial separation of the PSA from the polyethylene substrate was observed in most cases. Finite element (FE) peeling simulations were conducted which characterized the backing-membrane as an elasto-plastic power-law material, the PSA as a viscoelastic material and the interfacial properties with a cohesive zone model (CZM). The mechanical response of the backing membrane and the PSA were measured from tensile experiments while the rate-dependent cohesive zone parameters, i.e. the fracture energy and maximum stress, were measured directly from poker-chip probe tack tests. The numerical results from the CZM/FE simulations and the experimental values of the peel forces as a function of the peel angle, peel speed and PSA thickness were found to be in good agreement. Two different anti-fungal drugs were added to the PSA and the influence of the drug was investigated using contact angle measurements, tensile tests, dynamic mechanical analysis and peel tests.

Related Topics
Physical Sciences and Engineering Materials Science Materials Chemistry
Authors
, , ,