Article ID Journal Published Year Pages File Type
157390 Chemical Engineering Science 2010 9 Pages PDF
Abstract

Vapor–liquid equilibria of the carbon dioxide loaded sodium carbonate–water system were measured in the temperature range 40–80 °C and for sodium carbonate concentrations 8–12 wt%. In addition the vapor pressure of water over 10–30 wt% sodium carbonate solutions for the temperature range 27–100 °C was measured in an ebulliometer. The system was modeled using the electrolyte-NRTL model. Experimental vapor–liquid data from this study as well as data available in the literature from 25 to 195 °C and for sodium carbonate concentrations from 0.5 to 12 wt% were used for parameter fitting. The average deviation of the model predictions compared to all experimental data found is 9.8% for the partial pressure of CO2. For vapor pressure of water the standard deviation is 0.6% up to 100 °C and 30 wt% sodium carbonate solutions.

Related Topics
Physical Sciences and Engineering Chemical Engineering Chemical Engineering (General)
Authors
, , , , ,