Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
1576406 | Materials Science and Engineering: A | 2013 | 10 Pages |
Abstract
Four directional Carbon-Carbon composite was fabricated and thermo-physical properties were evaluated upto 1200 °C in different directions. Ablation behavior was studied with and without SiC coating in air plasma at a heat flux of 10 MW/m2 for 60 s. Thermo-physical properties are found to be almost same in all the directions. The average mass and linear ablation rates without coating were found to be 113.105 g/m2s and 0.06024 mm/s for while with coating these were 103.282 g/m2s and 0.0570 mm/s. Morphology of the ablated specimens has been discussed; the ablation starts at the weakest and porous primary carbon matrix.
Related Topics
Physical Sciences and Engineering
Materials Science
Materials Science (General)
Authors
Suresh Kumar, Juhi Kushwaha, Samar Mondal, Anil Kumar, R.K. Jain, G. Rohini Devi,