Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
158374 | Chemical Engineering Science | 2007 | 12 Pages |
The pressure drop and the dispersed phase drop size distribution have been measured for flow through SMX static mixer elements, in columns of diameter 41.18 and 15.75 mm, for a continuous phase of aqueous corn syrup and a dispersed phase of silicone oil. For single-phase flow the pressure drops were consistent with known literature correlations. In the presence of the dispersed phase the pressure drops were increased about 20% above the expected single-phase values, showing more short-term fluctuations but with no significant effect of the flow fraction of the dispersed phase. Droplet size distributions were measured by the computer-aided analysis of images from a digital camera. For shorter lengths of packing the distributions showed a significant “tail” at the large-diameter end, but as the packing length was increased the tail decreased or became non-existent. The mean drop sizes have been compared with a new model based on drop formation at equivalent point sources within the packing.