Article ID Journal Published Year Pages File Type
1629904 Journal of Iron and Steel Research, International 2006 5 Pages PDF
Abstract

The structure of laminar cooling control system for hot rolling was introduced and the control mode, cooling strategy, segment tracking and model recalculation were analyzed. The parameters of air/water cooling models were optimized by regressing the data gathering in situ, and satisfactory effect was obtained. The coiling temperature can be controlled within ± 15 °C.

Related Topics
Physical Sciences and Engineering Materials Science Metals and Alloys