Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
1659824 | Surface and Coatings Technology | 2010 | 7 Pages |
Mg alloy, AZ91D, which has a two-phase structure, was successfully electroplated in an alkaline Cu-plating bath. The Cu-coated Mg alloy specimen was further electroplated in eco-friendly acidic Cu and then trivalent Cr baths to obtain an anti-wear and anti-corrosion Cr/Cu coating. Experimental results show that the wear and corrosion resistance of the Mg alloy specimen was considerably improved by trivalent Cr electrodeposition. The hardness of the as-plated Cr deposit was drastically increased by using reduction-flame heating for 0.5 s. The above-mentioned results were measured via bonding strength, hardness, wear and corrosion tests. A superior wear and corrosion resistance was obtained when a Cu-coated Mg alloy specimen was electroplated with a trivalent Cr deposit, followed by heating with reduction-flame heating for 0.5 s.