Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
1660056 | Surface and Coatings Technology | 2008 | 5 Pages |
The aim of this work is the purification and the hydrogenation of metallurgical grade silicon for photovoltaic applications using a thermal plasma process. In addition to the plasma treatment, a DC bias of the liquid silicon was used to increase the kinetics of impurity extraction and hydrogenation reaction. On-line measurement by OES (Optical Emission Spectroscopy), ex-situ analysis by LIBS (Laser Induced Breakdown Spectroscopy) and ICP techniques demonstrated that elimination of metallic impurities and boron depends on the applied bias, and/or on the plasma gas composition. The DC bias was found to significantly increase the hydrogenation rate of liquid silicon, when it is attributed to electrochemical and/or chemical reactions in the electrical plasma sheath.