Article ID Journal Published Year Pages File Type
1684415 Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms 2007 5 Pages PDF
Abstract
Recently, our group proposed a method (proxy equilibrium factor method) using a bare LR 115 detector for long-term monitoring of the equilibrium factor. Due to the presence of an upper alpha-particle energy threshold for track formation in the LR 115 detector, the partial sensitivities to 222Rn, 218Po and 214Po were the same, which made possible measurements of a proxy equilibrium factor Fp that was well correlated with the equilibrium factor. In the present work, the method is extended to CR-39 detectors which have better-controlled etching properties but do not have an upper energy threshold. An exposed bare CR-39 detector is first pre-etched in 6.25 N NaOH solution at 70 °C for 6 h, and then etched electrochemically in a 6.25 N NaOH solution with ac voltage of 400 V (peak to peak) and 5 kHz applied across the detectors for 1 h at room temperature. Under these conditions, for tracks corresponding to incident angles larger than or equal to 50°, the treeing efficiency is 0% and 100% for incident energies smaller than and larger than 4 MeV, respectively. A simple method is then proposed to obtain the total number of tracks formed below the upper energy threshold of 4 MeV, from which the proxy equilibrium factor method can apply.
Related Topics
Physical Sciences and Engineering Materials Science Surfaces, Coatings and Films
Authors
, , ,